The APC APDU11452ME NetShelter Rack PDU Advanced Gen 2 is a high-density, metered power distribution unit designed for enterprise data centers and IT equipment racks. It supports 208V three-phase power and offers 42 outlets in a vertical 0U form factor. Integrated metering provides visibility into rack power usage, while Ethernet connectivity enables remote monitoring and management through compatible APC network management solutions.
| Brand | APC by Schneider Electric |
| Part Number / MPN | APDU11452ME |
| Product Type | Metered Rack Power Distribution Unit (PDU) |
| Product Family | NetShelter Rack PDU Advanced Gen 2 |
| Input Voltage | 208V AC, three-phase |
| Output Voltage | 208V AC |
| Maximum Input Current | 60A |
| Line Rated Current | 48A |
| Load Capacity | 17,300VA (17.3kW) |
| Input Plug | IEC 60309, 60A, 3P+PE |
| Total Outlets | 42 |
| Outlet Configuration | 21 × C13/C15/C19/C21 combination outlets; 21 × C13/C15 outlets |
| Metering Accuracy | 1% |
| Network Interface | Ethernet 10/100/1000 |
| Mounting | Vertical, 0U rack-mounted |
| Input Cord Length | 3m (9.8 ft) |
| Color | Black |
| Height | 70.08 in (1780 mm) |
| Width | 2.2 in (56 mm) |
| Depth | 3.0 in (75 mm) |
| Net Weight | 23.6 lbs (10.7 kg) |
Mount the APDU11452ME vertically in a compatible rack following APC installation instructions. Verify that the electrical supply matches the unit's 208V three-phase requirements and IEC 60309 input connector. Check the voltage, current, and connector requirements of all connected equipment before use. Network monitoring requires suitable network configuration and compatible management components. Installation should be performed by qualified personnel in accordance with local electrical codes.
1. What is the APC APDU11452ME?
It is a metered 0U rack PDU from the APC NetShelter Advanced Gen 2 family.
2. How many outlets does it provide?
It has 42 outlets, split between 21 combination C13/C15/C19/C21 outlets and 21 C13/C15 outlets.
3. What is its power capacity?
The specified load capacity is 17.3kW.
4. Does it support remote monitoring?
Yes. Ethernet connectivity supports compatible APC network management and EcoStruxure IT features.
5. What input connector does it use?
It uses an IEC 60309 60A 3P+PE plug.
6. How is the PDU mounted?
It is designed for vertical 0U mounting in a compatible rack.
DC Supplies recommends confirming the exact manufacturer part number, power supply, input connector, and outlet requirements before ordering. Specifications and availability may vary by region. Always follow manufacturer instructions and applicable electrical safety requirements.
All packages are shipped same day if the order is placed before 3PM CST
We use UPS/FedEx to ship the packages with different service levels offered by UPS/FedEx
Overnight Shipping take 1 business day
Expedited Shipping take about 2-3 business days
Ground shipping take about 3-5 business days
You can select the desired service level at Checkout and we will make sure the package is shipped as per the selected service level.
We Accept
i) PayPal
ii) All Credit & Debit Cards
iii) Purchase Orders
iv) Check
v) Bank Transfer/ACH/Wire Transfer
To process the order through Paypal/CC, you can simply checkout and process the payment.
If you want to issue us Purchase Order/Check/Bank Transfer, Please contact us at the following details
Call: 469.458.9636
Email: sales@dcsupplies.net
If you have any queries, please contact us at the following details and we will be happy to help
Call
469.458.9636
469.458.9638
Email
sales@dcsupplies.net
No customer reviews for the moment.

APC APDU11452ME NetShelter Metered Rack PDU
* Required fields
or Cancel