The Eaton EVMI4609X is a vertical, three-phase rack Power Distribution Unit (PDU) with local metering designed for large data center racks and enterprise IT power distribution. It is deployed by data center infrastructure engineers, network architects, and facilities teams to distribute AC power from a single three-phase feed to multiple IT loads while providing real-time electrical metering at the unit level. This model helps maintain awareness of load consumption and balance across outlets, which is critical for power planning, capacity management, and avoiding circuit overload in high-density racks.
The PDU supports a 208 V three-phase input at 60 A, delivering up to 17.3 kW of distribution capacity with a 460P9W IEC 60309 plug. It provides 42 outlets × 24 IEC C13 and 18 IEC C39 (combo) × enabling flexible connection of mixed rack equipment (e.g., servers, network switches, storage, PDUs). Local metering displays real-time load measurements for amperage, voltage, and kW to help infrastructure teams verify current draw and plan capacity.
Deployment is typically 0U vertical (0U/vertical mount) inside standard 42U server racks, saving valuable U-space for IT equipment. The narrow chassis and toolless mounting buttons enable front- or side-facing installation in crowded rack rows. The PDU's design also includes circuit breakers for each load bank, helping prevent overloads and enabling organized, color-coded outlet grouping for phase load balancing.
Integration with infrastructure management is supported via an Ethernet (RJ-45) network interface, enabling remote access and monitoring over SNMP or via Eaton's PDU management platform. While this model is "metered input" (without full outlet-level switching), it still provides essential rack-level power metrics and reporting critical for capacity planning and trending in enterprises.
A practical example is its use in a consolidation or core rack powering mixed compute and networking gear × the local metering helps verify balanced loading across phases and prioritize where additional PDUs or circuits may be required. In colocation facilities and large IT closets, this unit supports operational visibility without requiring managed outlet-by-outlet control.
This PDU is not suitable where fine-grained outlet switching or on/off control is required for remote power cycling of individual devices; "managed" or "switched" PDU models with outlet control should be used in those cases. Capacity planning also must account for three-phase distribution boundaries and rack load growth.
| Specification | Details |
|---|---|
| Brand | Eaton |
| Part Number | EVMI4609X |
| Product Type | Metered Rack PDU |
| Phase | Three-Phase |
| Input Voltage | 208 V AC |
| Input Connection | IEC 60309 460P9W |
| Input Current | 60 A |
| Output Capacity | ~17.3 kW |
| Outlets | 24 × IEC C13, 18 × IEC C39 |
| Mounting | 0U vertical |
| Cord Length | 10 ft (3.05 m) |
| Network Interface | Ethernet (RJ-45) |
| Metering | Local load metering display |
| Circuit Protection | Circuit breakers per load bank |
| Operating Temp | 0-60 °C |
| Certifications | cTUVus, UL 62368-1, UL 2900-1, IEC 62443-4-2 |
| Weight | ~25.35 lb |
| Dimensions (H×W×D) | 72″ × 2.56″ × 2.05″ |
All packages are shipped same day if the order is placed before 3PM CST
We use UPS/FedEx to ship the packages with different service levels offered by UPS/FedEx
Overnight Shipping take 1 business day
Expedited Shipping take about 2-3 business days
Ground shipping take about 3-5 business days
You can select the desired service level at Checkout and we will make sure the package is shipped as per the selected service level.
We Accept
i) PayPal
ii) All Credit & Debit Cards
iii) Purchase Orders
iv) Check
v) Bank Transfer/ACH/Wire Transfer
To process the order through Paypal/CC, you can simply checkout and process the payment.
If you want to issue us Purchase Order/Check/Bank Transfer, Please contact us at the following details
Call: 469.458.9636
Email: sales@dcsupplies.net
If you have any queries, please contact us at the following details and we will be happy to help
Call
469.458.9636
469.458.9638
Email
sales@dcsupplies.net
No customer reviews for the moment.

Eaton EVMI4609X 3 Phase Metered Input Rack PDU
* Required fields
or Cancel